* * PMRCCDOC - ENHANCED PMR PACKAGE - 06AUG95 - 12:00 - FLEX - PCC/DGB PAGE 1 * * ENHANCED PMR CHANNEL CODE DOCUMENTATION. THIS SECTION TO BE CUT OUT AND INSERTED * INTO THE CHANNEL CODE SECTION OF THE 1180M SYSTEM REFERENCE DOCUMENTATION LISTINGS. * *************************************************************************************** * ENHANCED PMR PACKAGE CHANNEL CODES ENTRY LIMITS ENT/DIS REV DATA *************************************************************************************** * 600 PMR DATA COLLECTION INTERVAL, SEC. (NSPMR) 0-32767 D/D PMRPLT A ZERO IS USED FOR EVENT DATA COLLECTION 601 PMR NUMBER OF VARIABLES TO COLLECT (NPMVAR) 1-20 D/D PMRPLT 602 PMR VARIABLE NUMBER [N] SELECT (KPMNUM) 1-20 D/D STANDARD 603 PMR VARIABLE [N] TYPE WORD (IPTYnn) 0-3092 B/B PMRPLT BCD FORMAT: S I I T S = SYMBOL/AUTO VARIABLE SCALE NIBBLE X X X X ^ ^ ^ ^---- AUTO-SCALING BIT (0=OFF; 1=ON) ^ ^ ^------ 0=USE IMAGE + OFFSET; 1=USE DATA DICTIONARY SYMBOL ^ ^-------- DON'T CARE ^---------- DON'T CARE SIMPLIFIED SETUP OF THE "S" NIBBLE: 0 = USE IMAGE + OFFSET ADDRESS; DON'T AUTO-SCALE 1 = USE IMAGE + OFFSET ADDRESS; AUTO-SCALE 2 = USE DATA DICTIONARY SYMBOL; DON'T AUTO-SCALE 3 = USE DATA DICTIONARY SYMBOL; AUTO-SCALE II = IMAGE NUMBER USED AS BASE ADDRESS; 00 = PSSD; OTHERS AS DEFINED IN PMR SETUP MODIFICATION "PMR_LINK". LIMITS FOR "II" ARE 0-9. T = VARIABLE TYPE (0=INT; 1=FP; 2=DWI) 604 PMR VARIABLE [N] ADDRESS (RELATIVE TO THE -99999 to 99999 F/F PMRPLT IMAGE THAT IS DEFINED IN TYPE CODE WORD) (-) ENTRIES ADD 100,000 TO THE ENTRY 605 PMR NUMBER OF SAMPLES COLLECTED (NSAMP) - -/D STANDARD 606 PMR VARIABLE [N] PLOT LOW VALUE (PPLLnn) PLOT LO VALUE F/F PMRPLT NOTES ON CHANNEL CODES THAT SET UP THE PMR VARIABLES (602-604 & 606-607): ALTHOUGHT THESE CHANNEL CODES CAN BE USED TO SET UP A PMR VARIABLE, THE SIMPLEST WAY IS TO DO THE SETUP OF A VARIABLE IS THROUGH THE SYSTEM CONSOLE BY CHANGING THE DATA IN THE APPROPRIATE PMR DISKETTE PRESET RECORD, PMRSET, RECORD [PMR PRESET NUMBER]. 608 PMR DISKETTE PRESET NUMBER READ (PMRPRN) 1-N D/D PMRPLT 609 PMR DISKETTE PRESET NUMBER WRITE (PMRPWN) 1-N D/D PMRPLT 615 PMR NUMBER OF SAMPLES PRINTED (ISAMP) - -/D PMRPLT * * PMRCCDOC - ENHANCED PMR PACKAGE - 06AUG95 - 12:00 - FLEX - PCC/DGB PAGE 2 * * ENHANCED PMR CHANNEL CODE DOCUMENTATION. THIS SECTION TO BE CUT OUT AND INSERTED * INTO THE CHANNEL CODE SECTION OF THE 1180M SYSTEM REFERENCE DOCUMENTATION LISTINGS. * *************************************************************************************** * ENHANCED PMR PACKAGE CHANNEL CODES ENTRY LIMITS ENT/DIS REV DATA *************************************************************************************** * 616 PMR VARIABLE [N] MINIMUM VALUE (PMINnn) 1-20 D/F PMRPLT 617 PMR VARIABLE [N] MAXIMUM VALUE (PMAXnn) 1-20 D/F PMRPLT 618 PMR VARIABLE [N] AVG VALUE (ONE-SHOT) (PAVGnn) 1-20 D/F PMRPLT 619 PMR VARIABLE [N] 2 SIGMA VALUE (ONE-SHOT) (P2SGnn) 1-20 D/F PMRPLT 620 PMR VARIABLE [N] VALUE SNAPSHOT (1x/SEC) (PMRVSS) 1-20 D/F PMRPLT NOTES ON CHANNEL CODES 616-620: CHANNEL CODES 616-620 ALLOW THE VARIABLE NUMBER TO BE ENTERED FOR "INSTANT DISPLAY" OF A VARIABLE'S DATA INSTEAD OF GOING BACK TO CHANNEL CODE 602 TO RE-ENTER THE VARIABLE NUMBER. BE AWARE THAT THE USE OF THIS FEATURE HAS THE SAME AFFECT AS SELECTING A VARIABLE USING CHANNEL CODE 602; I.E. KPMVAR IS CHANGED AND ALL PMR CHANNEL CODES WILL NOW BE ACCESSING THE DATA ASSOCIATED WITH THE NEW VARIABLE NUMBER. DUE TO THE LARGE AMOUNTS OF CALCULATION REQUIRED, THE AVERAGE AND 2 SIGMA ARE "ONE-SHOT" CALCULATIONS. 621 PMR PLOT SCALING / SEQUENCE (PMRPLF) -3 to +3 D/D PMRPLT NEGATIVE: AUTO-SCALING OF PLOT OFF POSITIVE: AUTO-SCALING OF PLOT ON (USING DATA UP TO START OF PLOT PRINTING) (THE AUTO SCALING LIMITS ARE DETERMINED DURING DATA COLLECTION) -3 = PLOTTED DATA (NO AUTO-SCALING), THEN NUMERIC DATA PRINTED -2 = NUMERIC DATA, THEN PLOTTED DATA (NO AUTO-SCALING) PRINTED -1 = PLOTTED DATA ONLY, (NO AUTO-SCALING) 0 = NUMERIC DATA ONLY 1 = PLOTTED DATA ONLY, (AUTO-SCALING) 2 = NUMERIC DATA, THEN PLOTTED DATA (AUTO-SCALING) PRINTED 3 = PLOTTED DATA (AUTO-SCALING), THEN NUMERIC DATA PRINTED 622 PMR COLLECT ON/OFF SELECT AND DISPLAY (IPMCPS) 0-1 B/B PMRPLT DISPLAY = 000CP (C = COLLECT, P = PRINT) 0=TURNED OFF, 1=REQUESTED, 2=IN PROGRESS, 3=COMPLETE 623 PMR PRINT ON/OFF SELECT AND DISPLAY (IPMCPS) 0-1 B/B PMRPLT DISPLAY = 000CP (C = COLLECT, P = PRINT) 0=TURNED OFF, 1=REQUESTED, 2=IN PROGRESS, 3=COMPLETE 624 SELECT PMR PRINTER NUMBER (IPMDVN) 1-4 D/D PMRPLT CORRESPONDING DEVICE MASKS ARE COLDSTARTED 625 SETUP PMR VARIABLE NUMBERS TO PLOT (PLTMSK) -32768 to 32767 D/O ENTRY > MAXPMV : PLOT ALL PMR VARIABLES (ALL BITS SET) ENTRY = N : SET VARIABLE "N" PLOT BIT IN PLOT MASK ENTRY = 0 : CLEAR ALL VARIABLE PLOT BITS IN PLTMSK ENTRY = (-N) : RESET VARIABLE "N" PLOT BIT IN PLOT MASK ENTRY < (-MAXPMV) : CLEAR ALL VARIABLE PLOT BITS IN PLTMSK NOTE: USING CHANNEL CODE 625 HAS THE SAME AFFECT AS SELECTING A VARIABLE USING CHANNEL CODE 602; I.E. KPMVAR IS CHANGED AND ALL PMR CHANNEL CODES WILL NOW BE ACCESSING THE DATA ASSOCIATED WITH THE NEW VARIABLE No. * * PMRCCDOC - ENHANCED PMR PACKAGE - 06AUG95 - 12:00 - FLEX - PCC/DGB PAGE 3 * * ENHANCED PMR CHANNEL CODE DOCUMENTATION. THIS SECTION TO BE CUT OUT AND INSERTED * INTO THE CHANNEL CODE SECTION OF THE 1180M SYSTEM REFERENCE DOCUMENTATION LISTINGS. * *************************************************************************************** * ENHANCED PMR PACKAGE CHANNEL CODES ENTRY LIMITS ENT/DIS REV DATA *************************************************************************************** * 626 SELECT PMR SETUP VIDEO PAGE -1 = SELECT LAST PAGE 0 = SELECT NEXT PAGE N = SELECT PAGE N (ERROR IF NON-EXISTENT) -1 to N D/D PMRPLT 630 PMR START DATA COLLECTION EVENT (PMRBEV) 0-29 D/D PMRPLT 631 PMR STOP DATA COLLECTION EVENT (PMRSEV) 0-29 D/D PMRPLT 632 PMR PRINT EVENT (PMRPEV) 0-29 D/D PMRPLT EVENTS FOR CHANNEL CODES 630-632: 0 - NULL (NO TRIGGERING EVENT) 1 - DEMAND A (CHANNEL CODE 633 ENTRY) (PMRACC) 2 - DEMAND B (CHANNEL CODE 634 ENTRY) (PMRBCC) 3 - REEL TURN UP FLAG (IRTFG) 4 - GRADE CHANGE (IGCFG) 5 - SHIFT CHANGE (ISHFT) 6 - DAY CHANGE (LOG27) 7 - SHEET BREAK (ISBFG) 8 - EDGE OF SHEET (LOG14) 9 - AUTO GRADE CHANGE REQUESTED (LOG28) 10 - MANUAL GRADE CHANGE REQUESTED (LOG29) 11 - AUTO GRADE CHANGE COMPLETED (LOG30) 12 - AUTO GRADE CHANGE ABORTED (LOG31) 13 - PMR DATA COLLECTION COMPLETED (LOPMRC) 14 - PMR DATA PRINTING COMPLETED (LOPMRP) 15 - PROCESS MEASUREMENTS ARE COMPLETED (LOG03) 16 - STANDARDIZE DATA ACCUMULATION COMPLETE (LOG25) 17 - 1 MINUTE LOGIC ORDINAL (LOG1MN - POLLER IMAGE) 18 - 1 HOUR LOGIC ORDINAL (LOG1HR - POLLER IMAGE) 19 - SPARE 20 - SPARE 21 - SPARE 22 - SPARE 23 - SPARE 24 - SPARE 25 - SPARE 26 - SPARE 27 - SPARE 28 - SPARE 29 - SPARE 633 PMR DEMAND "A" EVENT (PMRACC) ANY ENTRY D/D PMRPLT 634 PMR DEMAND "B" EVENT (PMRBCC) ANY ENTRY D/D PMRPLT